Coffee rings as low-resource diagnostics: detection of the malaria biomarker Plasmodium falciparum histidine-rich protein-II using a surface-coupled ring of Ni(II)NTA gold-plated polystyrene particles.

Gulka CP, Swartz JD, Trantum JR, Davis KM, Peak CM, Denton AJ, Haselton FR, Wright DW
ACS Appl Mater Interfaces. 2014 6 (9): 6257-63

PMID: 24758478 · DOI:10.1021/am501452k

We report a novel, low-resource malaria diagnostic platform inspired by the coffee ring phenomenon, selective for Plasmodium falciparum histidine-rich protein-II (PfHRP-II), a biomarker indicative of the P. falciparum parasite strain. In this diagnostic design, a recombinant HRP-II (rcHRP-II) biomarker is sandwiched between 1 μm Ni(II)nitrilotriacetic acid (NTA) gold-plated polystyrene microspheres (AuPS) and Ni(II)NTA-functionalized glass. After rcHRP-II malaria biomarkers had reacted with Ni(II)NTA-functionalized particles, a 1 μL volume of the particle-protein conjugate solution is deposited onto a functionalized glass slide. Drop evaporation produces the radial flow characteristic of coffee ring formation, and particle-protein conjugates are transported toward the drop edge, where, in the presence of rcHRP-II, particles bind to the Ni(II)NTA-functionalized glass surface. After evaporation, a wash with deionized water removes nonspecifically bound materials while maintaining the integrity of the surface-coupled ring produced by the presence of the protein biomarker. The dynamic range of this design was found to span 3 orders of magnitude, and rings are visible with the naked eye at protein concentrations as low as 10 pM, 1 order of magnitude below the 100 pM PfHRP-II threshold recommended by the World Health Organization. Key enabling features of this design are the inert and robust gold nanoshell to reduce nonspecific interactions on the particle surface, inclusion of a water wash step after drop evaporation to reduce nonspecific binding to the glass, a large diameter particle to project a large two-dimensional viewable area after ring formation, and a low particle density to favor radial flow toward the drop edge and reduce vertical settling to the glass surface in the center of the drop. This robust, antibody-free assay offers a simple user interface and clinically relevant limits of biomarker detection, two critical features required for low-resource malaria detection.

MeSH Terms (11)

Animals Antigens, Protozoan Biomarkers Gold Malaria, Falciparum Microscopy, Electron, Transmission Plasmodium falciparum Polystyrenes Protozoan Proteins Surface Properties Titanium

Connections (1)

This publication is referenced by other Labnodes entities:

Links