Multi-channel wireless mapping of gastrointestinal serosal slow wave propagation.
Paskaranandavadivel N, Wang R, Sathar S, O'Grady G, Cheng LK, Farajidavar A
(2015) Neurogastroenterol Motil 27: 580-5
MeSH Terms: Animals, Electrodes, Electrophysiological Phenomena, Female, Gastrointestinal Motility, Stomach, Swine, Telemetry, Wireless Technology
Show Abstract · Added April 26, 2016
BACKGROUND - High-resolution (HR) extracellular mapping allows accurate profiling of normal and dysrhythmic slow wave patterns. A current limitation is that cables traverse the abdominal wall or a natural orifice, risking discomfort, dislodgement or infection. Wireless approaches offer advantages, but a multi-channel system is required, capable of recording slow waves and mapping propagation with high fidelity.
METHODS - A novel multi-channel (n = 7) wireless mapping system was developed and compared to a wired commercial system. Slow wave signals were recorded from the porcine gastric and intestinal serosa in vivo. Signals were simultaneously acquired using both systems, and were filtered and processed to map activation wavefronts. For validation, the frequency and amplitude of detected events were compared, together with the speed and direction of mapped wavefronts.
KEY RESULTS - The wireless device achieved comparable signal quality to the reference device, and slow wave frequencies were identical. Amplitudes of the acquired gastric and intestinal slow wave signals were consistent between the devices. During normal propagation, spatiotemporal mapping remained accurate in the wireless system, however, during ectopic dysrhythmic pacemaking, the lower sampling resolution of the wireless device led to reduced accuracy in spatiotemporal mapping.
CONCLUSIONS & INFERENCES - A novel multichannel wireless device is presented for mapping slow wave activity. The device achieved high quality signals, and has the potential to facilitate chronic monitoring studies and clinical translation of spatiotemporal mapping. The current implementation may be applied to detect normal patterns and dysrhythmia onset, but HR mapping with finely spaced arrays currently remains necessary to accurately define dysrhythmic patterns.
© 2015 John Wiley & Sons Ltd.
0 Communities
1 Members
0 Resources
9 MeSH Terms
Prospective real-time head motion correction using inductively coupled wireless NMR probes.
Sengupta S, Tadanki S, Gore JC, Welch EB
(2014) Magn Reson Med 72: 971-85
MeSH Terms: Artifacts, Brain, Computer Systems, Equipment Design, Equipment Failure Analysis, Fiducial Markers, Head Movements, Humans, Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, Magnetics, Male, Miniaturization, Motion, Reproducibility of Results, Sensitivity and Specificity, Transducers, Wireless Technology
Show Abstract · Added January 23, 2014
PURPOSE - Head motion continues to be a major source of artifacts and data quality degradation in MRI. The goal of this work was to develop and demonstrate a novel technique for prospective, 6 degrees of freedom (6DOF) rigid body motion estimation and real-time motion correction using inductively coupled wireless nuclear magnetic resonance (NMR) probe markers.
METHODS - Three wireless probes that are inductively coupled with the scanner's RF setup serve as fiducials on the subject's head. A 12-ms linear navigator module is interleaved with the imaging sequence for head position estimation, and scan geometry is updated in real time for motion compensation. Flip angle amplification in the markers allows the use of extremely small navigator flip angles (∼1°). A novel algorithm is presented to identify marker positions in the absence of marker specific receive channels. Motion correction is demonstrated in high resolution 2D and 3D gradient recalled echo experiments in a phantom and humans.
RESULTS - Significant improvement of image quality is demonstrated in phantoms and human volunteers under different motion conditions.
CONCLUSION - A novel real-time 6DOF head motion correction technique based on wireless NMR probes is demonstrated in high resolution imaging at 7 Tesla.
Copyright © 2013 Wiley Periodicals, Inc.
0 Communities
2 Members
0 Resources
18 MeSH Terms
A miniature bidirectional telemetry system for in vivo gastric slow wave recordings.
Farajidavar A, O'Grady G, Rao SM, Cheng LK, Abell T, Chiao JC
(2012) Physiol Meas 33: N29-37
MeSH Terms: Animals, Dogs, Electrophysiological Phenomena, Fourier Analysis, Gastrointestinal Motility, Male, Miniaturization, Stomach, Telemetry, Wireless Technology
Show Abstract · Added April 26, 2016
Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical userinter face. The front-end module conditions the analogue signals, then digitizes and loads the data into a radio for transmission. Data receipt at the backend is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35 × 35 × 27 mm3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124 h operation when utilizing a 560 mAh, 3 V battery. In vivo,slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles min−1), automated activation time detection was modestly better for the wireless system (5% versus 14% FP rate), and signal amplitudes were modestly higher via the wireless system (462 versus 3 86μV; p<0.001). This telemetric system for slow wave acquisition is reliable,power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients.0967-3334/