, a bio/informatics shared resource is still "open for business" - Visit the CDS website


Other search tools

About this data

The publication data currently available has been vetted by Vanderbilt faculty, staff, administrators and trainees. The data itself is retrieved directly from NCBI's PubMed and is automatically updated on a weekly basis to ensure accuracy and completeness.

If you have any questions or comments, please contact us.

Results: 1 to 3 of 3

Publication Record

Connections

Linear Accelerator-Based Stereotactic Radiosurgery for Cranial Intraparenchymal Metastasis of a Malignant Peripheral Nerve Sheath Tumor: Case Report and Review of the Literature.
Fenlon JB, Khattab MH, Ferguson DC, Luo G, Keedy VL, Chambless LB, Kirschner AN
(2019) World Neurosurg 123: 123-127
MeSH Terms: Adult, Brain Neoplasms, Humans, Magnetic Resonance Imaging, Male, Nerve Sheath Neoplasms, Neurofibrosarcoma, Particle Accelerators, Positron-Emission Tomography, Radiosurgery
Show Abstract · Added April 2, 2019
BACKGROUND - Malignant peripheral nerve sheath tumors (MPNSTs) are rare, aggressive soft tissue sarcomas. MPNST intracranial metastasis is exceedingly rare with only 22 documented cases in the literature and, to our knowledge, only 1 case with intraparenchymal brain metastasis. Most have been managed surgically; however, 2 documented cases were treated with Gamma Knife radiosurgery. Excluding this case report, there are no other documented cases of linear accelerator-based stereotactic radiosurgery (SRS) to treat MPNST brain metastasis.
CASE DESCRIPTION - A 41-year-old man with MPNST of the lung initially underwent tumor resection. He developed multiple systemic metastases that were managed with directed radiation therapy. A parietal brain metastasis was treated with linear accelerator-based SRS. Following SRS therapy, the patient was treated with a tropomyosin receptor kinase inhibitor. Complete resolution of brain metastasis was seen on brain magnetic resonance imaging 5 months after treatment with SRS. At 11 months after SRS, there was no evidence of recurrence or progression of the intraparenchymal disease. The patient continued to have stable extracranial disease on his ninth cycle of systemic treatment.
CONCLUSIONS - This report provides important insights into efficacy of linear accelerator-based SRS to treat MPNST brain metastases.
Copyright © 2018 Elsevier Inc. All rights reserved.
0 Communities
1 Members
0 Resources
MeSH Terms
Characterization of a high-purity germanium detector for small-animal SPECT.
Johnson LC, Campbell DL, Hull EL, Peterson TE
(2011) Phys Med Biol 56: 5877-88
MeSH Terms: Animals, Electromagnetic Fields, Equipment Design, Gamma Cameras, Germanium, Image Enhancement, Models, Animal, Particle Accelerators, Phantoms, Imaging, Reproducibility of Results, Sensitivity and Specificity, Tomography, Emission-Computed, Single-Photon
Show Abstract · Added May 30, 2014
We present an initial evaluation of a mechanically cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axes. Finally, a flood-corrected flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT.
0 Communities
1 Members
0 Resources
12 MeSH Terms
Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams.
Newhauser W, Koch N, Hummel S, Ziegler M, Titt U
(2005) Phys Med Biol 50: 5229-49
MeSH Terms: Computer Simulation, Dose-Response Relationship, Radiation, Eye Neoplasms, Humans, Monte Carlo Method, Particle Accelerators, Phantoms, Imaging, Protons, Radiation Dosage, Radiotherapy Planning, Computer-Assisted, Radiotherapy, High-Energy
Show Abstract · Added February 22, 2013
By the end of 2002, 33 398 patients worldwide had been treated with proton radiotherapy, 10 829 for eye diseases. The dose prediction algorithms used today for ocular proton therapy treatment planning rely on parameterizations of measured proton dose distributions, i.e., broad-beam and pencil-beam techniques, whose predictive capabilities are inherently limited by severe approximations and simplifications in modelling the radiation transport physics. In contrast, the Monte Carlo radiation transport technique can, in principle, provide accurate predictions of the proton treatment beams by taking into account all the physical processes involved, including coulombic energy loss, energy straggling, multiple Coulomb scattering, elastic and nonelastic nuclear interactions, and the transport of secondary particles. It has not been shown, however, whether it is possible to commission a proton treatment planning system by using data exclusively from Monte Carlo simulations of the treatment apparatus and a phantom. In this work, we made benchmark comparisons between Monte Carlo predictions and measurements of an ocular proton treatment beamline. The maximum differences between absorbed dose profiles from simulations and measurements were 6% and 0.6 mm, while typical differences were less than 2% and 0.2 mm. The computation time for the entire virtual commissioning process is less than one day. The study revealed that, after a significant development effort, a Monte Carlo model of a proton therapy apparatus is sufficiently accurate and fast for commissioning a treatment planning system.
0 Communities
1 Members
0 Resources
11 MeSH Terms