Raman-shifted alexandrite laser for soft tissue ablation in the 6- to 7-µm wavelength range.

Kozub J, Ivanov B, Jayasinghe A, Prasad R, Shen J, Klosner M, Heller D, Mendenhall M, Piston DW, Joos K, Hutson MS
Biomed Opt Express. 2011 2 (5): 1275-81

PMID: 21559139 · PMCID: PMC3087584 · DOI:10.1364/BOE.2.001275

Prior work with free-electron lasers (FELs) showed that wavelengths in the 6- to 7-µm range could ablate soft tissues efficiently with little collateral damage; however, FELs proved too costly and too complex for widespread surgical use. Several alternative 6- to 7-µm laser systems have demonstrated the ability to cut soft tissues cleanly, but at rates that were much too low for surgical applications. Here, we present initial results with a Raman-shifted, pulsed alexandrite laser that is tunable from 6 to 7 µm and cuts soft tissues cleanly-approximately 15 µm of thermal damage surrounding ablation craters in cornea-and does so with volumetric ablation rates of 2-5 × 10(-3) mm(3)/s. These rates are comparable to those attained in prior successful surgical trials using the FEL for optic nerve sheath fenestration.